25.
Object 2100h: Set DEMO mode
This message enables the Demo mode function. Demo mode is a special feature that
consists in different LED states for each button pressing. Refer to the appendix “Demo
mode instructions” to try these special features. Disconnect and reconnect the keypad after
the sending the message to enter this mode. To exit the Demo mode, send the Disable
Demo mode command or another command message.
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
00h
CAN Object 2100h
Byte 2
21h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Example:
Direction
Identifier
Format Message
Data
To Keypad
615
Std
2F 00 21 00 01 00
00 00
Set DEMO mode
Active
Keypad
reply
595
Std
60 00 21 00 00 00
00 00
Command accepted
26.
Object 1016h: Consumer heartbeat time
The consumer heartbeat time object shall indicate the expected heartbeat cycle times.
Monitoring of the heartbeat producer shall start after the reception of the first heartbeat.
NOTE 1: the heartbeat consumer time should be greater (typically twice) than the related
heartbeat time to be monitored coming from the producer.
NOTE 2: if the keypad does not receive the heartbeat message producer anymore, it turns
off all the LEDs eventually ON (both indicators and backlight) and goes to pre-operational
state until a new NMT start message is received, even if the producer restarts to transmit
the heartbeat.
NOTE 3: if the consumer heartbeat time is set with a value lower than the producer one,
the keypad will not be able to change its state from pre-operational to operational.
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
23h
Set device Register
Byte 1
16h
CAN Object 1016h
Byte 2
10h
Byte 3
ZZh
00h: Highest sub-index supported (read-
only)
01h: Sub-index (read/write)
Byte 4
YYh
YYh: Heartbeat time in milliseconds
LSByte
Byte 5
XXh
XXh: Heartbeat time in milliseconds
MSByte
Byte 6
NNh
Node to be monitored
01h-7Fh (01h default)
Byte 7
00h
Reserved