3.
Default settings
Setting
Default state or level
How to change
Baud Rate
125 kbit/s
Object 2010h
CANopen Node ID
15h
Object 2013h
Device active on startup
Not active
Object 2012h
Default LED indicators
brightness
3Fh (Maximum Brightness)
Object 2003h
Default backlight brightness
00h (OFF)
Object 2003h
Default backlight color
Amber
Object 2003h
Startup LED Light Show
Complete LED Sequence
Object 2014h
Periodic key-state transmission
Disabled
Object 1800h
DEMO mode
Disabled
Object 2100h
Heartbeat producer
Disabled
Object 1017h
Heartbeat consumer
Disabled
Object 1016h
Boot-up service
Active
Object 2011h
RPDO 200h transmission type
Event-driven
Object 1400h
RPDO 300h transmission type
Event-driven
Object 1401h
TPDO 180h transmission type
Event-driven
Object 1800h
NMT MESSAGES
The Network Management messages follow a master-slave structure. Through NMT
services, CANopen devices are initialized, started, reset or stopped.
NMT messages have CAN-ID always equal to 00h.
4.
Start CANopen node (keypad activation message)
Identifier
00h
Byte 0
01h
Start CANopen node
Byte 1
XXh
Keypad CAN ID
00h: start all the keypads
15h: start the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
01 15
5.
Enter pre-operational
Identifier
00h
Byte 0
80h
Enter pre-operational
Byte 1
XXh
Keypad CAN ID
00h: enter all the keypads
15h: enter the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
80 15