Object 1011h: Restore default parameters
With this object the default values of parameters according to the communication profile,
device profile, and application profile are restored. This procedure shall only be executed
when the specific signature ‘’load’’ is written to the sub-index 01h. When the message
shown in the following table is transmitted, the default values shall be restored after the
keypad is reset.
Identifier
615h (600h + current
CAN ID)
Byte 0
40h
Read Device Register
23h
Set Device Register
Byte 1
11h
CAN Object 1011h
Byte 2
10h
Byte 3
00h
Highest sub-index supported
01h
Restore all parameters
Byte 4
6Ch
Character 1 ‘’l’’
Byte 5
6Fh
Character 2 ‘’o’’
Byte 6
61h
Character 3 ‘’a’’
Byte 7
64h
Character 4 ‘’d’’
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 11 10 00 00 00 00 00 Read highest sub-
index
Keypad reply
595
Std
4F 11 10 00 01 00 00 00 1
To Keypad
615
Std
23 11 10 01 6C 6F 61 64 ‘load’
Keypad reply
595
Std
43 11 10 01 00 00 00 00 Command
accepted
35.
Object 1018h: Identity Data
Identifier
615h (600h + current CAN ID)
Byte 0
40h
Read Device Register
Byte 1
18h
CAN Object 1018h
Byte 2
10h
Byte 3
00h
Number of mapped objects
01h
Vendor Id
04h
Serial number
Byte 4,7
00h
Not used
Examples:
Direction
Identifier Format
Message
Data
To Keypad
615
Std
40 18 10 00 00 00 00 00
Keypad reply
595
Std
4F 18 10 00 04 00 00 00
4
To Keypad
615
Std
40 18 10 01 00 00 00 00
Keypad reply
595
Std
43 18 10 01 E2 03 00 00
000003E2h
Blink Marine Vendor Id: 000003E2h