Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 12 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
FOR REFERENCE ONLY
Examples:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 02 20 01 01 00
00 00
Set red LED #1
blink
Keypad reply
595
Std
60 02 20 01 00 00
00 00
Command
accepted
To Keypad
615
Std
2F 02 20 03 10 00
00 00
Set blue LED #5
blink
Keypad reply
595
Std
60 02 20 03 00 00
00 00
Command
accepted
b)
Read LED blink
•
PKP 1500LI
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
02h
CAN Object 2002h
Byte 2
20h
Byte 3
XXh
XX: Sub index
01h: Red LED
02h: Green LED
03h: Blue LED
Byte 4,7
00h
Not used
Examples:
Direction
Identifier Format Message
Data
To Keypad
615
Std
40 02 20 01 00 00
00 00
Read red LED blink
Keypad reply
595
Std
4F 02 20 01 1F 00
00 00
All red LED blink
To Keypad
615
Std
40 02 20 02 00 00
00 00
Read green LED blink
Keypad reply
595
Std
4F 02 20 02 02 00
00 00
Only green LED #2
blinks
To Keypad
615
Std
40 02 20 03 00 00
00 00
Read blue LED blink
Keypad reply
595
Std
4F 02 20 03 00 00
00 00
No blue LED blinks
19.
Object 2003h: Brightness Level
a)
LED indicators brightness level:
Set message:
Identifier
615h (600h + current CAN ID)
Byte 0
2Fh
Set Device Register
Byte 1
03h
CAN Object 2003h
Byte 2
20h
Byte 3
01h
Sub index
Byte 4
YYh
Intensity 00h-3Fh
à
min-100%
Byte 5,7
00h
Not used
Read message: