Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 18 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
FOR REFERENCE ONLY
22.
Object 2012h: Set device active on startup
If keypad is active on startup don’t need the Start CANopen command from host.
Set message:
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
12h
CAN Object 2012h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
00h: Not active
01h: Active
Byte 5,7
00h
Not used
Read message:
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
12h
CAN Object 2012h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4,7
00h
Not used
Example:
Direction
Identifier
Format
Message
Data
To Keypad
615
Std
2F 12 20 00 01 00
00 00
Device active on
startup
Keypad
reply
595
Std
60 12 20 00 00 00
00 00
Command accepted
To Keypad
615
Std
40 12 20 00 00 00
00 00
Read command set
Keypad
reply
595
Std
4F 12 20 00 01 00
00 00
Device active on
startup
23.
Object 2013h: Set CANopen node ID
Set message:
Identifier
600h + current CAN ID
Default 615h
Byte 0
2Fh
Set Device Register
Byte 1
13h
CAN Object 2013h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4
XXh
XX: New node id (01h-7Fh),
default 15h
Byte 5,7
00h
Not used
Read message:
Identifier
600h + current CAN ID
Default 615h
Byte 0
40h
Read Device Register
Byte 1
13h
CAN Object 2013h
Byte 2
20h
Byte 3
00h
Sub index
Byte 4,7
00h
Not used