16
LAN SOLUTION NETWORK TESTER
APPLICATION HINTS
Any patch cables used to connect the tester and remote to
a cable run must be “short” compared to the cable run for
accurate open and split pair indication. “Short” patch cables
must be no more than 10% of the total run length or 3 feet
(0.9 m), whichever is less. A cable must be at least 4 feet
(1.2 m) long for a single-ended test to work properly.
3.3 To Place a Tone on a Cable
1. Connect the cable you want to trace to the main
unit. Press the CABLE button to turn on the
tester. Press the CABLE button again until Tone
Generator is displayed, then press the SEL button.
2. Press the SEL button until the desired tone is
selected. Use the up/down arrow keys to select the
pin or pair(s) to carry the tone.
3. For the strongest signal, do not connect the
remote. Since twisted pairs have a shielding effect,
the strongest signal is obtained by having only one
wire of a pair carry a tone. Selecting a single pin
instead of a pair will do this.
3.4 To Measure the Length of a Cable
1. Connect the cable to the main unit. A remote may
be at the other end, but it’s not required.