Specifications
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes
over an ambient temperature range of 23 °C ± 5 °C. Specifications are subject to change
without notice.
Model
9832
9833
AC Output
Output Phase
Single
Max. Power
2000 VA
3000 VA
Voltage Range
1
(rms)
Low
0 to 150 V
High
0 to 300 V
Current
(rms)
Low
20 A
30 A
High
10 A
15 A
Current
(peak)
Low
65 A (< 100 Hz)
50 A (> 100 Hz)
97.5 A (< 100 Hz)
75 A (> 100 Hz)
High
32.5 A (< 100 Hz)
25 A (> 100 Hz)
48.75 A (< 100 Hz)
37.5 A (> 100 Hz)
Frequency Range
45 to 1.2 kHz
Phase Range
0 to 359.7
Total
45 to 400 Hz
0.5 %
Harmonic
> 400 to 1 KHz
1 %
Distortion
2
> 1 k to 1.2 kHz
2 %
Line Regulation
3
0.1%
Load Regulation
3
0.1% (resistive load)
Temperature Coefficient
0.2% per °C
Crest
Factor
45 to 100 Hz
3.25
100 Hz to 1.2 kHz
2.25
Efficiency
4
80 % (typical)
DC output
Maxium Power
1000 W
1500 W
Voltage Range
1
Low
0 to ±212 V
High
0 to ±424 V
Current
Low
10 A
15 A
High
5 A
7.4 A
Ripple and Noise (20 Hz to 20 MHz)
≦
300 mVrms /
≦
3 Vpp
Output Characteristics
Transient Response Time
1.5 ms (typical)
Output Impedance
≦
1 ohm