53
Figure 56 - Event Switch Diagram
To activate this function, connect to pin 13 (E) and pin 25 (Event_SW-), and then
give switch on/off command through SCPI command.
Command
Description
TEST:DIGI ON
TEST:DIGI:IO:SWITCH ON
TEST:DIGI:IO:SWITCH OFF
TEST:DIGI OFF
To activate the switch on/off function
Switch on
Switch off
To disable the switch on/off function
Table 22 - Event Switch Commands
Note: DIGI must be set ON to make changes to the switch on/off state.
12.8
Analog input (BNC)
The analog input(BNC) is used to control the output voltage of the instrument with an
external signal. In this example, an Arbitrary waveform generator is connected
.
Figure 57 Configuration 1 page
www.
GlobalTestSupply
.com
Find Quality Products Online at: