IXNET dialogs
Operating instructions iS10 / iS20
72
38019417000 en
7
Weight status GT0A
Example
21010000
: Tare weighed, no motion, overload, outside zero setting range
digit
Function
Meaning
1
Tare identification
Definition of tare
1 = tare not active
2 = weighed tare
3 = tare preset, manual value (EDP)
2
No motion
0 = unstable
1 = stable
3
Underload
0 = no underload
1 = underload
4
Overload
0 = no overload
1 = overload
5
Zero setting range
0 = outside zero setting range
1 = in zero setting range
6
Not assigned
0
7
Not assigned
0
8
Not assigned
0
Total recording
Command
Response
Description
I!RX07
I!GV01|<Subcmd>|LX02
(on EDP channel)
Total recording
The following return values can be configured in step 78, PC/EDP parameter menu:
GL15
Consecutive number
GL0A
Item counter
GD1D
Total of gross weight
GD1E
Total of tare weight
GD1F
Total of net weight
GW06
Record number
GV02
Data block 1-10 (additional character set)