Operating instructions iS10 / iS20
IXNET dialogs
38019417000 en
73
7
Tare with value definition
Command
Response
Description
I!GD02|kg;-3;50
I!LW00|770
or
I!LV00|LW01|
Error number
|LW02|770|LX02
Possible errors
3031
Tare value incorrect
3036
Transmitted weight value has incorrect dimension
Writing tolerance control value
Command
Response
Description
I!CV06|CD02|kg;-3;800|CD08|kg;-3;1000|CD03|
kg;-3;1200|LX02
I!LW00|9734
or
I!LV00|LW01|
Error number
|LW02|9734|LX02
Reading tolerance control values
Command
Response
Description
I?CV06|LX02 I!CV06|CD02|kg;-3;400|CD08|kg;-3;500|CD03|kg;-3;600|
LX02
CD02
Tolerance minus
CD08
Target value
CD03
Tolerance plus
Possible errors
3036
Transmitted weight value has incorrect dimension
24871
Tolerance parameter values are not correct
Start tolerance control
Command
Response
Description
I!CX01
I!LW00|8193