Operating instructions iS10 / iS20
PC/EDP and printer interface
38019417000 en
57
6
Selection
Subselection
Display
Explanation
or
71 9600
Baud rate
115_
115200 bit/s
Setting changes with
each keystroke.
57600
57600 bit/s
38400
38400 bit/s
19200
19200 bit/s
9600
9600 bit/s
4800
4800 bit/s
or
72 E7
Parity and data bit
E7
even parity, 7 data bits
Setting changes with
each keystroke.
o7
odd parity, 7 data bits
n7
no parity, 7 data bits
E8
even parity, 8 data bits
o8
odd parity, 8 data bits
n8
no parity, 8 data bits
or
73 03
Separator 03H (hex) ETX
00
off
Setting changes with
each keystroke.
01
01 H (Hex)
to
1F
1 FH
20
CR and LF
or
74 00
Logic acknowledgments (only data dialog
standard)
0
off
1
on
or
75 00
System number
00
Setting changes with
each keystroke.
to
99