PC/EDP and printer interface
Operating instructions iS10 / iS20
52
38019417000 en
6
Sign:
SP
(20H) = positive value
-
(2DH) = negative value
Scale: Underload or overload:
Is marked in the status byte. All decades including g and kg are marked
X
(58H).
Gross weight
Example:
Gross weight 10.475 kg;
Scale 15 kg/0.005 kg
Example:
Gross weight 25.8 kg;
Scale 30 kg/0.01 kg
Net weight
Additive weighing of weighed
tare weight
Net weight
Subtractive weighing of weigh-
ed tare weight
Tare values
Taring not active
Tare weight weighed
Tare weight manual tare (EDP)