Service menu
Operating instructions iS10 / iS20
80
38019417000 en
9
Selection
Subselection
Display
Explanation
or
10 0
Parallel inputs and outputs
0
Control cable and LED not active
Setting changes with
each keystroke.
1
Control cable active
2
LED active
3
Control cable and LED active
or
11 0
± operating mode of tendency control
0
Weighing as from zero.
Display of difference as compared to target val-
ue.
1
Weighing against zero.
Display of absolute weight value
or
n000000
Internal standardized measured value for service
purposes.
L100000
Internal linearized measured value for service
purposes.
or
ln 000
Diagnosis for control cables Input
(Taring, clear tare and item recording adding)
000
Inputs not active
111
Inputs active
or
oU 0000
Diagnosis for control cables Output
(lower tolerance limit, target value, upper toler-
ance limit, standstill)
0000
Outputs not active
1111
Outputs active
or
12 0
Taring after recording
0
Function not active
Setting changes with
each keystroke.
1
Function active