BT-780 Operation manual
13
P/N : 780-ENG-OPM-EXP-R00
Bistos Co., Ltd.
2020.03
[Trend]
Trend display
[Print]
Print key
[Settings]
Setup menu
[Volume]
Volume setup key
[Unlock]
Touch screen lock key
1.8 Essential performance
This device Multi-parameter Patient Monitor provides various patient vital signs such as pulse rate, ECG, respiration, blood oxygen
saturation, blood pressure and temperature by placing or inserting the various sensors to the appropriate site of patient. The device
is composed with display and control circuit, and input part for various sensors. It detects ECG, SpO2, NIBP, etc. using ECG cable and
specific probes and sensors. The detected analog signal amplifies and converted to digital. This concerted data feed to the CPU and
converted to the display format as number and waveform. This device is incorporated with alarm system. The alarm generated
when the detected signal range is beyond the user set alarm limits.
2 Preparing for operations
2.1 Installation
To ensure normal working of the monitor, read this chapter before use, and install as required.
WARNING
All analog and digital devices connected to the monitor must be certified by IEC standards (e.g. IEC 60950 Data
processing equipment standard and IEC 60601-1 Medical equipment standard). Furthermore, all configurations
shall comply with valid version of IEC 60601-1 standard. The personnel connecting additional devices to the input /
output signal ports are responsible for the compliance with IEC 60601-1 standard. If there is any question, please
contact Bistos.
If the patient cable interface and network interface are connected with multiple devices, the total electric leakage
current cannot exceed the allowable value.
The copyright of monitor software belongs to our company. Without permission, any organization or individual
shall not interpolate, copy or exchange by any means or form.
When the monitor is combined with other devices, it must comply with IEC 60601-1:2005 + A1:2012, and should
not be connected with multiple socket outlet or extension cord.
Do not connect the device on other equipment or network, to which a signal input/output part may be connected.
Prior to installation, the operator must ensure that the following space, power, environmental requirements are met.
2.1.1 Unpack and check
BT-780 patient monitor was inspected rigorously at the factory before delivery, in order to avoid being hit when transported, carried
out careful packaging. Before unpacking, carefully inspect the package. If any damage, please immediately contact the Bistos.
Unpack in the correct way, carefully remove the monitor and accessories from the box and check with the packing list. Check if
there is any mechanical damage, the all listed are completely packed. If you have questions, please contact the marketing
department of Bistos or agency.
Please keep the packing box and materials for use in future transporting or storage.
2.1.2 Placement requirements
Equipment installation must meet:
-
The left and right side of the monitor should have space more than 100 cm from the wall
-
Back on the monitor should have space more than 50 cm.
-
Ensure that the operating floor and the monitor have enough space for connecting the accessory wires.
2.1.3 Power requirements
-
AC power supply power cord
Input voltage: A.C. 100 V - 240 V,
Input current: 0.8-0.3A
Frequency: 50/60 Hz
-
Built-in rechargeable lithium-ion battery: D.C. 11.1 V, 4400 mAh
2.1.4 Environmental requirements
The storage, transport and use of the monitor must meet the following environmental requirements.
Operating
environment
Ambient temperature
5
℃
~ 40
℃
Relative humidity
30 % ~ 85 % (Non-condensing)
Atmospheric pressure
700 ~ 1060 mbar (hPa)
Transportation
Prevent severe shock, vibration, rain and snow splashing during transport.