INSTALLATION MANUAL
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product’s performance. The product is supplied with
a “
Warnings
” leaflet and an “
Instruction booklet
”. These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336/EEC and
73/23/EEC (and subsequent amendments).
1) GENERAL SAFETY
• The “ Warnings ” leaflet and “ Instruction booklet ” supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according to
the provisions set out by current standards. Keep nylon and polysty-rene
bags out of children’s reach.
• Keep the instructions together with the technical brochure for future refer-
ence.
• This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences result-
ing from improper use, or use which is different from that expected and
specified in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments. As for all non-EEC countries, the above-mentioned
standards as well as the current national standards should be respected
in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
• The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subse-
quent amendments.
• Disconnect the electrical power supply before carrying out any work on
the installation.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
• Check that earthing is carried out correctly: connect the automation
system to earth.
• Only use original parts for any maintenance or repair operation. The Com-
pany declines all responsibility with respect to the automation safety and
correct operation when other manufacturers’ components are used.
• Do not modify the automation components, unless explicitly authorised
by the company.
• Instruct the installation user about the control systems provided.
• Do not allow persons or children to remain in the automation operation
area.
• Keep radio control or other control devices out of children’s reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automa-
tion system, but always request the assistance of qualified personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.
2) GENERAL OUTLINE
Operator used to motorise residential and industrial sectional doors.
Thanks to its compactness and fitting versatility, this operator can be installed
in different ways.
Safety microswitches protect each manual manoeuvre command. The
motor is provided with an electromagnetic brake to make the gearmotor
irreversible.
The following versions are available:
ULISSE-C
Version with manual opening and closing.
ULISSE-CM
Version with manual chain opening and closing, and release for mainte-
nance (the release mechanism disengages the motion drive from the door
cable-winder shaft).
ULISSE-SB
Version with quick release for fast manual opening and closing.
The power supplied to the accessories connected to the limit switches of
the auxiliary contacts must be rated at 5 A max.
TABLE 1 - TECHNICAL SPECIFICATIONS
MODEL
Power supply
Motor
Single-phase
Three-phase
N. poles
6
4
6
4
Output revs - Reduction ratio
22 min
-1
- 43
33 min
-1
- 43
22 min
-1
- 43
33 min
-1
- 43
Power
500 W
600 W
770 W
720 W
Max torque
45 Nm
40 Nm
65 Nm
65 Nm
no
240
168
500
500
yes
27.5 revs
no
yes
-
F
Capacitor
Insulation class
Through shaft
Shaft with pinion
Max door weight
*
Electromechanical, incorporated and adjustable
Limit devices
Stroke
Manual manoeuvre
ULISSE C*:
Chain winch
Chain winch and quick release
Quick release
ULISSE CM**:
ULISSE SB***:
N. manoeuvres 24/h
Environmental conditions
10 Kg
Operator weight
Degree of protection
IP20
ULISSE C*
ULISSE CM**
ULISSE SB***
ULISSE S C*
ULISSE S CM**
ULISSE S SB***
ULISSE S C*
ULISSE S CM**
ULISSE S SB***
ULISSE C*
ULISSE CM**
ULISSE SB***
230V
10% 50Hz
400V
10% 50Hz
* Depends on door construction type, refer to max. torque. This value is indicative.
12
-
ULISSE - Ver. 05
D
81
14
01
_0