Maintenance
5-26
Maintenance
Quantum Flex
®
Air Operating Instructions and Parts List
Manual No. 107193
November 1, 2018
Power Unit / Head Assembly - Attachment and Adjustment
(Continued)
Step 11:
Blade Installation
– Large Tools (Continued)
Models: 750, 850, 1000, 1300, 1400, 1500, 1850, 1880
Blade is too loose
If the blade is too loose in the housing, adjustments can be made by slightly loosening the left
cover retaining screw and squeezing the housing lightly. Check the housing for proper running
clearance and retighten the left cover screw to 35 in-lb. (4 N-m). Use of the Bettcher
®
torque
wrench kit is recommended.
COMPANY