Maintenance
5-6
Maintenance
Quantum Flex
®
Air Operating Instructions and Parts List
Manual No. 107193
November 1, 2018
Disassembly of Handpiece
(Continued)
Sharp blades may cause cut injury!
For proper protection of hands, a protective glove
should be used when operating this equipment and
during the handling of blades.
Always disconnect the tool from the air supply prior
to servicing.
Step 3: Blade Removal
– Small Tools
Models: 350, 360, 440, 500, 505, 564, 620, 625
Hold the tool in your hand with the blade edge facing upward.
Loosen the two blade housing
mounting screws.
Using ¼" nut driver turn the cam
clockwise about 1/8 of a turn until it
locks the housing in the open position.
Remove the blade from the blade
housing.
Hold the tool with
the blade side up.
Loosen only the left
cover retaining screw.
WARNING
HOUSING IN
OPEN POSITION
BLADE HOUSING MOUNTING
SCREWS
¼” NUT
DRIVER
CLOCKWISE