n
Manual and Auto-select mode
Manual and Auto-select Listen-in can be integrated.
This will allow the User to select (manually) specific lo-
cations during standby status.
Use 4 Outputs for Manual-select Listen-in mode, and 4
Outputs for Auto-select listen-in mode.
The Outputs must be connected in two’s — one Manual
and one Auto, as shown in Figure 57.
To ensure proper functioning of Auto-select mode, the man-
ually controlled Outputs must be in standby status. There-
fore, the Outputs must always be restored to Standby when
a manually controlled listen-in session ends.
K3-PRT Printer Interface
!
Disconnect the Mains and battery power before
starting the installation procedure.
The optional K3-PRT Printer Interface will allow you to
connect the Control panel to a parallel printer for:
—
Real-time
printout of events (refer to “Accessories”
under “Configuration” in the Programming” section);
—
Entire Logger
printout (refer to “Print Logger” under
“Keypad Codes – User” in the Programming” section
and/or “Event Logger” under “Operating your system
from a Keypad” in the USER MANUAL);
—
Specific events
printout (refer to “ Logger — Events
Setup” under “Programming”).
n
Identification of Parts
The following Table describes the parts illustrated in
Figure 58. The numbers in boldface in this section, refer
to parts in Figure 58 (unless otherwise specified).
No.
DESCRIPTION
118
Interface connector
119
Printer connector
n
Connecting the Printer
If you prefer to chase the lead, use a plug-free cable (re-
fer to Table 12 for the wiring specifications and see also
Figure 59). Moulded plug leads (usually supplied with
the printer) cannot be chased.
n
Installation instructions
Work carefully through the following steps (see Fig-
ure 58 and Figure 3 on page 11).
1.
Lay the cable between the printer and the Control
panel.
2.
Plug the Printer interface into the connector
15
on
the Control panel PCB then, using the screws, se-
cure it in place.
KYO 300-KYO100
APPENDIX
93
SPK+
SP+
SP+
SP+
SP+
SPK-
RL1
RL1
SP-
SP-
SP-
SP-
MIC
RL2
OC2
OC2
OC2
L2
OC4
OC4
OC4
L4
OC3
OC3
OC3
L3
OC1
OC1
OC1
L1
RL2
RL3
+12
+F
+12
RL3
RL2
RL2
MIC
MIC
MIC
MIC
Voice board
Output exp. 01
Input exp. 01
Omnia/4R
Omnia/4R
1 Voice module
st
2 Voice module
nd
3 Voice module
rd
4 Voice module
th
+12
*
*
*
*
Connect ONLY the [+] terminals of the
board to the terminal [+12] of
the Voice Board. The [+] terminals of
Keypads must be connected
to the [+] terminal of the Control panel.
VOX-REM
Alison-DV
*
Figure 57
Wiring for Manual-select Listen-in mode