Contact ID
Event Codes must comprise 2 digits. If
you enter one digit only, the application will auto-
matically add the letter A ( e.g. 1 will be changed
to A1).
1 ... 8
These Numbers represent the Digital Communi-
cator Telephone Numbers that will be called when the
Action occurs.
The Digital Communicator Numbers are represented by
their ID Number (see
No.
column on the
Digital Commu-
nicator
page). To select/deselect a Digital Communicator
Number, double click on the relevant cell (
YES
indicates
that the Digital Communicator Number will be called).
+
If you associate an Action with a Digital Communicator
Number which transmits in
CONTACT ID
,
TELIM
,
CESA
or
SIA
Reporting Format, any other Digital
Communicator Numbers, assigned to the Action in
question, must transmit in the same Reporting Format.
All
If this option is Enabled, the Control Panel will call
all the numbers when the corresponding Action occurs.
If this option is Disabled (at default), the Control Panel
will terminate the call cycle after the first successful call.
To enable (
Y
) this option, press
ENTER
or double click
on the relevant cell.
Description
This editable field is for the Action label.
Events
This button will allow you to select the Events
that will trigger the Action.
CONTACT ID
If the selected telephone number is as-
sociated with CONTACT ID, it is possible to associate
this reporting format automatically to priority events, by
selecting and confirming CONTACT ID (see the Figure
below).
Auxiliary Communicator (KYO 300 only)
This Control panel can manage a
K3-AuxCom
Auxil-
iary Communicator (accessory item). If the Control
panel blocks, this backup device will takeover the com-
munication transmissions (refer to “Auxiliary Communi-
cator K3-AuxCom” in the “APPENDIX”).
The Auxiliary Communicator can send a different Cus-
tomer Code and Event Code to up to 8 Telephone Num-
bers.
The layout of the
Auxiliary Communicator
page is as
follows.
+
The
Auxiliary Communicato
r parameters cannot
be programmed until
The Auxiliary Communica-
tor Present
option (
Accessories
page) has been
Enabled.
Telephone Number to call
Enter the required Tele-
phone number (maximum 20 characters).
Valid entries: digits 0 through 9, pound (#), star (*) and
comma (,).
Use the comma for dialling pauses (e.g. between a
switchboard number and telephone number).
Protocol
This field will allow you to select the Central
Station Reporting Format (refer to “Protocol” under
“Digital Communicator”).
Customer Code
This field is for the Control panel ID
Code — assigned by the Central Station (refer to “Sys-
tem Code” under “Digital Communicator”).
Event code
This field is for the Control panel “Blocked”
Code — assigned by the Central Station (refer to
“Codes” under “Digital Communicator).
Call successful numbers
If this option is enabled, the
Auxiliary Communicator will dial all the programmed
telephone numbers. If this option is Disabled (at de-
fault), the Control Panel will terminate the call cycle af-
ter the first successful call.
Voice Messages
This function is provided by the
K3-VOX
Voice Board (ac-
cessory item). The
K3-VOX
will allow the Control Panel to
manage up to 62 Voice Messages with programmable
quality and length. The amount of message time available
depends on the sound quality of the messages, and
KYO 300-KYO100
PROGRAMMING
55
Figure 39
Digital Communicator window