Autoreset on Arming
If this option is enabled (at de-
fault), the system will
Reset Partition Alarms
each
time it is Armed (refer to “Reset Partition Alarms” under
“Keypad Codes — Code Types”).
Timer Associated Arming
This option provides the
system with an Arm command filter. If a Timer is associ-
ated with the Partition, the system will execute com-
mands to Arm the Partition ONLY when the Timer is
‘ACTIVE’ and the programmed ‘ON Time’ is running
(refer to “Scheduler - Timers”). Commands to Arm the
Partition during the programmed ‘OFF Time’ will be de-
nied.
Timer associated Disarming
This option provides
the system with a Disarm command filter. If a Timer is
associated with the Partition, the system will execute
commands to Disarm the Partition ONLY when the
Timer is ‘ACTIVE’ and the respective ‘ON Time’ is run-
ning (refer to “Scheduler - Timers”). Commands to Dis-
arm the Partition during the respective ‘OFF Time’ will
be denied.
Telephone
The
Telephone
page will allow you to program:
Ø
the Telephone numbers for the Digital Communica-
tor, Dialler, Auxiliary Communicator and Teleservice
facilities;
Ø
Telephone line parameters;
Ø
the Answering Machine parameters.
The layout of the
Telephone
page is as follows.
No.
This field shows the Telephone ID number. This
number will be used instead of the Description (User la-
bel) in some parts of the application.
Telephone Number
This editable field (maximum 20
digits) is for the Telephone number the system will call.
Valid entries: digits from 0 to 9, pound (#), star (*) and
comma (,).
The comma can be used to insert pauses, for example,
between a switchboard number and a telephone number.
Description
This editable field (maximum 16 charac-
ters) is for the Telephone Number label (e.g. User
Name).
The
Description
at default is [Tel. Number
nnn
] — (
nnn
represents the ID number of the Telephone Number).
Used by
This programming section will allow you to
assign the Telephone facilities:
Ø
Dial. = Dialler
Ø
Dig. = Digital Communicator
Ø
Tel. = Teleservice
n
Answer
The
Answer
section will allow you to program the Con-
trol Panel answer mode.
+
The Control Panel cannot answer incoming calls
when the Answering Machine or Teleservice facil-
ity is Disabled (refer to “Enable/Disable
Teleservice” and “Enable/Disable Answering Ma-
chine” in the USER’S MANUAL).
Rings
This field will allow you to program the number
of rings the Control panel must allow before answering
an incoming call.
+
If the
Double call
option is enabled, the number of
Rings
will be ignored (refer to “Double call” under
“Teleservice”).
n
Dialling
The Dialling section will allow you to program the Con-
trol Panel Dialling mode.
Line Check
If this option is Enabled, the system will
supervise the telephone line.
The system will signal “Line down” (i.e. voltage on the
[L.E.] terminals less than 3V for over 45 seconds) by:
KYO 300-KYO100
PROGRAMMING
49
Figure 34
Telephone page