1.
Remove all power from the Control panel (Mains
and battery).
2.
Remove the jumper
21
(M).
3.
Wait at least 20 seconds.
4.
Replace the jumper
21
(M).
5.
Restore power to the Control panel (refer to “Con-
necting the Power Supply” under “INSTALLING THE
KYO300”).
!
Jumper 21 (M) must be disconnected for at
least 20 seconds in order to ensure full reset of
the factory default programming, and to avoid
problems that may occur when the power sup-
ply is restored.
Installer code locked
If the
Lock Installer code
op-
tion is enabled, the Installer PIN will not be able to reset
to factory default (refer to Lock Installer code in the Op-
tions section).
Reporting Formats
This paragraph describes the structures of the main re-
porting formats supported by the system.
n
TELIM
The TELIM protocol transmits as follows:
Ø
User Code
(4 digits — 0 through 9);
Ø
Event Code
:
41
in the event of Alarm or Tamper on the
first 16 zones of the Control panel,
0
in all other cases;
Ø
2 byte (16 bit) representing the status of the first 16
zones —
0
Standby;
1
= Alarm or Tamper.
n
Contact ID
Contact ID transmits as follows:
Ø
User Code
(4 hexadecimal digits — 0 through F );
Ø
Qualifier: 1
= new event or Disarming operation;
3
event restore event or Arming operation
Ø
Class Code
(
CL.
column): identifies the type of
event (Alarm, Trouble, Fire, etc.);
Ø
Event Code
(
CODE
column): identifies the event
(Event Codes can be changed, refer to “Actions” un-
der “Digital Communicator” in the “PROGRAMMING”
section);
Ø
Group Number
(
GROUP
column), where possible,
identifies the Partition of the “object” which gener-
ated the event;
Ø
Zone Number
(
ZONE
column), where possible,
identifies the “object” (Zone, Code, Key, etc.) which
generated the event.
n
SIA
SIA is a FSK (Frequency Shift Keying) format, that
transmits alternatively in two slightly different frequen-
cies. The frequency shift is usually 170 Hertz, and the
two frequencies are associated with 0 and 1 of the bi-
nary digit which transmits the following data:
Ø
User Code
(4 digits — 0 through 9)
Ø
Function Code
(1 digit; N=new event, O=restore event)
Ø
Date
(month-day-year)
Ø
Time
(hour-minutes-seconds)
Ø
Event Type
(refer to the
TYPE
column in Table 13)
Ø
Event Agent
(refer to the
1
st
and
2
nd
columns in Ta-
ble 13).
New features
This section describes the new features of the Up-
graded KYO300.
+
The Control panel release can be read on the Mi-
croprocessor (see Part no.
39
on page 11), or on
any of the system Keypads, by means of the Re-
lease option from the INSTALLER MENU.
n
KYO300 1.10
Enable/Disable Timer
This feature allows User Codes to enable/disable the
Timers.
Turn ON/OFF Timers
This feature allows the Control panel to record all Timer
operations (ON/OFF) in the Event Logger.
96
Receiver
GRN
RED
Panel
YEL
BLK
GRN
RED
YEL
BLK
Figure 61