3.
Connect the Printer lead to the connector
119
on
the Printer Interface.
K3-AuxCom Auxiliary Communicator
!
Disconnect the Mains and battery power before
starting the installation procedure.
The K3-AuxCom Auxiliary Communicator (accessory item
for KYO 300 only) supports the most widely used reporting
formats. It manages up to 8 Telephone numbers. Each of
which can be associated with a different User and Event
Code. The K3-AuxCom will trigger the programmed event
calls when the Control panel Microprocessor blocks.
n
Installation
Please read this section to get an overall view of the
steps involved in installing the K3-AuxCom Auxiliary
Communicator (see Figure 3 page 11).
1.
Insert the K3-AuxCom into the Auxiliary Communi-
cator connector
19
on the Control panel PCB then,
Using the screws, secure it firmly in position.
2.
Remove the jumpers
18
and
48
to enable the Auxil-
iary Communicator.
+
The K3-AuxCom cannot function when jumpers
18
and
48
are inserted.
If you disconnect the K3-AuxCom, you must
RE-INSERT jumpers
18
and
48
, otherwise, the Con-
trol panel will be isolated from the Telephone line.
VectorRX Receiver
The VectorRX Receiver (accessory item) will allow your sys-
tem to manage up to 32 Wireless detectors (PIRs, Magnetic
Contacts, Smoke detectors), and up to 16 Wireless keys.
Please read this section to get an overall view of the
steps involved in installing the VectorRX Receiver.
n
Identification of Parts
The following Table describes the components of the
VectorRX Receiver (see Figure 60). The numbers in
boldface in this section, refer to the descriptions in the
Table and Figure.
No.
DESCRIPTION
120
Spring catch slots (2)
121
Anchor screw locations (3 x ø 4.6 mm)
122
Antennas (2)
123
Microprocessors (2)
124
Snatch Microswitch
125
Tamper button
126
Screws (2)
127
Wire entry (10 x 6.4 mm)
94
118
119
Figure 58
Printer Interface components
18
20
21
22
23
24
25
Printer side:
Centronics connector, male:
pins from 15 to 17 and 19 through 30
must be connected together
and to pin 19 of the DB25 connector
18 wire shielded cable
:
the shield must be soldered
to the metallic casing
of both connectors
(max. length 10 m)
Interface side:
DB25
connector
male
13
12
11
10
9
8
7
6
5
4
3
2
1
14
15
16
17
19
1
2
3
4
5
6
7
8
9
10
11
12
13
14
16
17
15
18
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
Figure 59
Wiring diagram of parallel printer cable
Interface connector: DB25 connector, male
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
19
18 wire cable + shield: the shield must be soldered to the metal casing of both connectors
1
2
3
4
5
6
7
8
9
10
11
12
13
14
32
31
36
15÷17/19÷30
Printer side: Centronics connector, 36 pin, male
Table 12
Wiring diagram of the cable between the parallel printer and the Printer Interface