RReedduucciinngg tthhee rruunnnniinngg ssppeeeedd
By setting the
dip switch 6 to ON, the motor only runs at half speed. At half
speed, the centrifugal mass of a door is lower and thus, among other things,
the forces required at the closing edge can be better maintained. After switch-
ing the speed, the control unit must be reset so that the running times and
forces can be taught in again.
1199..
TTaarrggeetteedd O
OPPEEN
N // CCLLO
OSSEE
The two inputs
Pulse / CLOSE and Partial opening / OPEN can be switched to
the
Targeted OPEN / CLOSE function with and without panic function using dip
switches 7 and 8. Switching from impulse / partial opening function to targeted
OPEN / CLOSE has no influence on the function of the radio channels.
If one of the OPEN or CLOSE inputs is actuated during a motor run for targeted
OPEN / CLOSE with panic function, the motor stops (soft stop). For targeted
OPEN / CLOSE without panic function, actuation of the input for the current
direction has no effect during a motor run. When the input for the opposite
direction is actuated, the running direction is changed.
If both inputs are actuated simultaneously, the motor always stops immediate-
ly without a soft stop.
IMPULSE – Function:
S1.7 = OFF
S1.8 = OFF
Targeted OPEN / CLOSE without panic
function
S1.7 = ON
S1.8 = OFF
Targeted OPEN / CLOSE with panic func-
tion
S1.7 = OFF
S1.8 = ON
2200..
DDeeaadd--m
maann m
mooddee
To activate the dead man's mode, switch dip switches 7 and 8 to ON.
The motor will then run in the desired direction only as long as the input is ac-
tuated. Radio operation is not possible during dead man operation.
23
2211..
SSaaffeettyy ddeevviiccee ((DDIIPP ssw
wiittcchh)) 11 ++ 22
WARNING
Risk of injury during door movement!
In the area of the door system, damage or injuries can occur during door
movements. The gate wing can collide with persons who are in the movement
area of the gate and (seriously) injure them. Limbs can be caught by the gate
and taken along. There is a risk that limbs that get between the sliding gate
and fixed parts of the system could be cut off.
SAFETY INSTRUCTIONS FOR HAZARD AVOIDANCE
Children and animals must be kept away from the gate system when the
gate is moving. Children are
not allowed to play at the gate system.
Make sure that neither persons nor objects are in the path of the gate.
The free space between the gate wing and the floor must be selected in
such a way that there is no danger of the feet being carried along.
If possible, the door should only be operated when there is visual con-
tact with the movement range of the door.
Monitor the door movement until the door has reached its end position.
During opening and closing of the gate, the working area of the gate sys-
tem must
not be entered or passed through!
Do
not stand still in the opened door system!
If possible, install an emergency stop command device in order to be
able to trigger an immediate stop in an emergency.
S2.1
Entrance LS / SE 1
ON
=
8k2 Safety edge
OFF
=
Light barrier
S2.2
Entrance LS / SE 2
ON
=
8k2 Safety edge
OFF
=
Light barrier