12
55..
CCiirrccuuiitt ddiiaaggrraam
m 4477--2211--((88 uu.. 1111--AA))
NOTE
Remote terminal strip at: Ultra VA, Genios 350, Genios.
Mains
230 V
Warning
light
230 V
3-min. light
230 V
impulse partial
opening
Emergency
stop
Main closing
edge ./
light barrier
secondary
closing edge
./
light barrier
24 V AC
max.
0,5 A
L
N
PE
L
N
L
N
potential-free
1
2
3
4
5
6
7
8
9
10 11 12 13
14
15
16
17 18
13
66..
TTeerrm
miinnaall bblloocckkss
An extra terminal strip was installed in the control box for easy wiring.
1
mains L
2
mains N
3
mains PE
4
warning light 230 V AC
5
warning light 230 V AC
6
3-minutes-light 230 V
7
3-minutes-light 230 V
8
Touch buttonmpulse/Closed
9
touch button - shared
10
touch button partial opening
11
stop
12
stop
13
main closing edge
14
main closing edge
15
secondary closing edge
16
secondary closing edge
17
24 V AC max. 0,5 A
18
24 V AC max. 0,5 A
77..
lluum
miinnoouuss ddiiooddeess
LED Mains green: Operating voltage is present
LED radio yellow: radio - reception / learning / deleting
LED Error red: Display error / self-test
88..
BBuuttttoonn
radio – button: learn radio / learn partial opening / delete radio /
reset control
Pulse - button: Pulse operation / Reset control system
Terminal 8, 9, 10; function depending on posi-
tion of dip-switch
7
ON
targeted OPEN / CLOSE
OFF
touch button
Terminal
11, 12
13, 14
15, 16
Unused inputs must
be bridged. Connec-
tions according to
points 21.1, 22 of
these instructions