WARNING
Interventions in a defective gate system by unqualified
persons can lead to serious injuries!
The use of a defective door system can lead to serious personal injury and ma-
terial damage.
SAFETY INSTRUCTION FOR DANGER AVOIDANCE
In case of malfunctions or incorrect operation, the mains plug must be
pulled out
immediately.
The repair may only be carried out by competent persons!
Existing errors and / or defects must be repaired
immediately and com-
pletely!
An attempt by an unqualified person to repair a defective door system
or to intervene in any other way can lead to serious injuries!
Before carrying out any work, disconnect the door system from the
power supply and secure the door system against unauthorized recon-
nection
To arrange for an inspection of the door system or maintenance work, contact
your specialist dealer.
BELFOX Torautomatik GmbH
Tel: +49 6655 9695 0
Forsthaus 4
Fax: +49 6655 9695 31
36148 Kalbach
Email: [email protected]
Germany
31
2277..
TTeecchhnniiccaall ddaattaa
Power supply:
230V AC +10% / -15%
2x 24 V AC +/- 5V With center tap
Operating frequency:
50Hz
Power consumption:
Stand by: 2 x 24V, je 25mA, with HF-Module
Outputs:
Motor 24V
DC
Light output 230V
AC
max. 100W
Warning light output 230V
AC
max. 100W
Transformator 230V
AC
max. 200W
Light + Warning light + transformator together max. 350W
24V
AC
500mA
Inputs:
230V AC with L
Transformator secondary 2 x 24V
AC
with center tap
Impulse/close
(pot.-free closing)
Partial opening
(pot.-free closing)
Light barrier/SE1
(pot.-free opener/8k2)
Light barrier/SE2
(pot.-free opener/8k2)
Stop
(pot.-free opener)
Reference Switch open (pot.- free closing)
Reference Switch closed (pot.- free opener)
Antenna
Ground connection for antenna shielding
Radio:
Multipoint connector with 15 poles for connection with radio
module
Operating
temperature:
Environmental temperature electronics
-20°C to +50°C at max. 5.5A motor current with 80s runtime.
At higher currents the running time is reduced or the use of
heat sinks is required.