7.3 Setting the rotary encoding
switches
7 Starting operation
7.3.1 Factory reset
A factory reset restores the original factory settings and thus resets the
changes and settings you have made up to that point. It also resets the
protocol selection. To perform a factory reset, set the first rotary encoding
switch (x100) to 9, the second (x10) to 7, and the third (x1) also to 9.
Afterwards perform a power cycle and wait 10 seconds due to internal
memory write processes.
During the factory reset, the U
S
LED is blinking red. After the internal memory
write processes have finished, the U
S
LED returns to display static green or
red light, in dependency of the actual U
S
voltage.
x100
x10
x1
Factory Reset
9
7
9
Follow the steps from section
Setting the rotary encoding switches
36 again to select a new protocol.
For performing a factory reset via software configuration, see chapter
on page 105 and the configuration section.
Manual EtherCAT®
Version 1.1 04/2021
38