10 IIoT functionality
10.2 OPC UA
Feature
Support
Managing IODDs
(chapter 6.1.6 in the specification)
Not supported
Mapping IODD information to OPC UA ObjectTypes
(chapter 6.3 in the specification)
Not supported
IOLinkIODDDeviceType
(chapters 7.2 ff. in the specification)
Not supported
ObjectTypes generated based on IODDs
(chapters 7.3 ff. in the specification)
Not supported
Creation of Instances based on ObjectTypes generated out of
IODDs
(chapter 7.4 in the specification)
Not supported
IODDManagement Object
(chapter 8.2 in the specification)
Not supported
RemoveIODD Method
(chapter 8.3 in the specification)
Not supported
Table 23: Non-supported OPC UA features according to the IO-Link
Companion Specification
10.2.1 OPC UA configuration
The OPC UA Server can be configured either using the Web interface or
directly via a JSON Object sent in an HTTP request. For more information
OPC UA configuration - Quick start guide
on page 108.
The configuration URL is:
http://[ip-address]/w/config/opcua.json
The configuration can also read back as a JSON file:
http://[ip-address]/r/config/opcua.json
The configuration is a JSON object. Each member is a configuration element.
The object must not contain all elements. Only the provided elements will be
changed. All configuration changed applies only after a device restart.
Manual EtherCAT®
Version 1.1 04/2021
105