10 IIoT functionality
10.3 REST API
10.3.2 Structure
Name
Data type
Description
Example
name
string
Device name
"0980 XSL 3912-
121-007D-00F"
order-id
string
Ordering number
"935 700 001"
fw-version
string
Firmware version
"V.1.1.0.0 -
01.01.2021"
hw-version
string
Hardware version
"V.1.00"
mac
string
MAC address of the device
"3C B9 A6 F3 F6
05"
bus
number
0 = No connection
1 = Connection with PLC
1
failsafe
number
0 = Normal operation
1 = Outputs are in failsafe
0
ip
string
IP address of the device
snMask
string
Subnet Mask
gw
string
Default gateway
rotarys
array of numbers (3) Current position of the rotary switches:
Array element 0 = x1
Array element 1 = x10
Array element 2 = x100
ulPresent
boolean
True, if there is a UL voltage supply
detected within valid range
usVoltage_mv
number
US voltage supply in mV
ulVoltage_mv
number
UL voltage supply in mV (only
available for devices with UL supply)
inputs
array of numbers (2) Real state of digital inputs.
Element 0 = 1 Byte:
Port X1
Channel A to Port X4 Channel B
Element 0 = 1 Byte:
Port X5
Channel A to Port X8 Channel B
\[128,3\]
output
array of numbers (2) Real State of digital outputs.
Element 0 =1 Byte:
Port X1
Channel A to port X4 Channel B
Element 0 = 1 Byte:
Port X5
Channel A to port X8 Channel B
\[55,8\]