EN
Installation and operating manual
DRYPOINT
®
M eco control
35
7.1.3.
Replace the filter element and float drain
Exchange the filter element and the float drain once every year in accordance with the maintenance schedule.
Further information about exchanging spare parts is included on a leaflet with the spare parts.
Prerequisites
Tools
Material
Protective equipment
• Mounting too
l
•
Filter element
•
Float drain
Preparatory tasks
1.
1.
Depressurise the device and secure against pressure being applied again:
Depressurise the device and secure against pressure being applied again:
2.
2.
De-energise the device and secure it against being switched back on again.
De-energise the device and secure it against being switched back on again.
Remove the mains plug.
Remove the mains plug.
A “click” noise indicates the opening of the solenoid valve.
A “click” noise indicates the opening of the solenoid valve.
Pressure drop is taking place in the device.
Pressure drop is taking place in the device.
Maintenance work
7
6
8
10
13
9
!
20.. 20.. 20..
Ye
ar
Mont
h
NEXT ELEMENT
CHANGE
DRYPOINT
®
M
eco control
11
16
7
4
12
[4]
Eco label
[6]
Filter element
[7]
O-rings (housing)
[8]
Housing extension
[9]
Maintenance label: Filter replacement
[10]
Housing base
[11]
Housing body with membrane element
[12]
Membrane dryer head
[13]
Float drain
[16]
Mounting tool for float drain