Installation and operating manual
EN
42
DRYPOINT
®
M eco control
9. Hang the electronic printed circuit board carefully over
the housing edge by the cables.
10. Replace the solenoid coil:
• Use pointed pliers to pull the connector out parallel to
the surface of the electronic printed circuit board.
•
Consequences of non-compliance:
Damage to the plug connection possible.
Only hold the electronic printed circuit board by the
narrow edges.
11. Replace the solenoid coil.
Insert the new connector onto the pins as far as it will
go parallel to the surface of the electronic printed circuit
board.
12. Loosen the screws on the pilot valve seat using an Allen
key.
The pilot valve seat is raised upwards by the force of the
spring underneath it.
Ø = 2,5 mm
M = 0,5 Nm + 10 %
Ø = 2,5 mm
M = 0,5 Nm + 10 %