EN
Installation and operating manual
DRYPOINT
®
M eco control
5
1.2. Signal words according to ISO 3864 and ANSI Z.535
DANGER
Imminent hazard
Consequences of non-compliance: serious or even fatal injury
WARNING
Potential hazard
Consequences of non-compliance: possibly serious or even fatal injury
CAUTION
Imminent hazard
Consequences of non-compliance: injury and/or damage to property
NOTE
Additional notes, information, tips
Consequences of non-compliance: Disturbances during operation and maintenance.
No hazard to persons.
1.3. Safety instructions
DANGER
Escaping compressed gas
Risk of serious or even fatal injury from suddenly released compressed gas, condensate or
unsecured system components.
• Before carrying out any assembly, installation or maintenance work, depressurise the system.
These works may only be executed by authorised skilled technical personnel
1
.
• Use only pressure-resistant installation materials and suitable tools that are in proper working
order.
• Before pressure build-up, check all unit parts and repair them, if necessary. Open valves slowly
to prevent pressure blow outs in operating state.
•
Always prevent people or objects from being affected by condensate or escaping compressed
gas.
• Prevent vibrations, oscillations and impact from being transferred to system parts.
• Perform a leakage test.
DANGER
Mains voltage
Risk of electric shock with serious or even fatal injuries if contact is made with non-insulated, live
components.
•
Observe all applicable regulations with respect to electrical installations (e.g. VDE 0100 / IEC
60364).
• Only execute installation and maintenance works when the system has been de-energised.
• Electrical works may only be executed by authorised skilled technical personnel
1
.
•
Read off the permissible operating voltage on the type plate and always comply with it.
• Only utilise components for the electrical installation which have current authorisation
and are labelled with a CE-Identification Marking.
• A safely accessible circuit breaker (e.g. power plug or switch) must be provided close to the unit
for disconnecting all current and/or power lines for the voltage supply.
WARNING
Operation outside of limit values
If the specified limit values are undershot and/or exceeded, there is a risk of device malfunction,
potentially resulting in injury and/or damage to property.
• The device must only be operated for the intended purpose and within the permissible limits
specified on the type plate and in the technical data.
• Strictly adhere to the prescribed operating times and maintenance intervals.
•
Strictly adhere to the prescribed storage and transport conditions.
1
Skilled technical personnel
Skilled technical personnel are people who, due to their professional qualification and knowledge in the field of measuring,
control and pneumatic technology, and their knowledge of the applicable statutory regulations, guidelines and standards
are in a position to independently foresee potential dangers in relation to the use of the device and who are qualified to
perform the tasks described in this manual. Special operating conditions e.g. aggressive media require additional knowledge.