Installation and operating manual
EN
18
DRYPOINT
®
M eco control
PDP inlet
Volume flow inlet in ll/minute at 10 bar
+35 °C
+20 °C
+5 °C
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C
628
837
1256
1674
2318
2721
3220
4911
6521
+5°C
-5°C
499
660
990
1320
1835
2157
2576
3832
5120
+10°C
0°C
-10°C
393
523
797
1055
1465
1723
2061
3059
4089
+5°C
-5°C
-15°C
335
448
671
895
1256
1473
1755
2657
3526
0°C
-10°C
293
390
586
781
1103
1296
1562
2383
3156
-5°C
-20°C
261
348
522
696
990
1167
1401
2141
2850
-10°C
-15°C
240
319
478
638
910
1071
1296
1980
2624
-15°C
-20°C
-26°C
219
293
440
586
837
982
1199
1819
2415
-20°C
-26°C
204
272
407
544
779
918
1111
1691
2238
-26°C
190
253
380
507
728
853
1030
1570
2093
PDP outlet
41
55
82
110
158
185
226
343
452
10 bar
Purge air in l/minute at 10 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.
PDP inlet
Volume flow inlet in ll/minute at 9 bar
+35 °C
+20 °C
+5 °C
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C
546
728
1092
1456
2016
2366
2800
4270
5670
+5°C
-5°C
434
574
861
1148
1596
1876
2240
3332
4452
+10°C
0°C
-10°C
342
455
693
917
1274
1498
1792
2660
3556
+5°C
-5°C
-15°C
291
389
584
778
1092
1281
1526
2310
3066
0°C
-10°C
255
339
510
679
959
1127
1358
2072
2744
-5°C
-20°C
227
302
454
605
861
1015
1218
1862
2478
-10°C
-15°C
209
277
416
554
791
931
1127
1722
2282
-15°C
-20°C
-26°C
190
255
382
510
728
854
1043
1582
2100
-20°C
-26°C
178
237
354
473
678
798
966
1470
1946
-26°C
165
220
330
441
633
742
896
1365
1820
PDP outlet
38
50
75
100
144
169
206
313
413
9 bar
Purge air in l/minute at 9 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.
PDP inlet
Volume flow inlet in ll/minute at 8 bar
+35 °C
+20 °C
+5 °C
DEC
1-30S
DEC
2-40S
DEC
3-60S
DEC
4-80S
DEC
5-115S
DEC
6-135S
DEC
7-165S
DEC
8-250S
DEC
9-330S
+10°C
464
619
928
1238
1714
2011
2380
3630
4820
+5°C
-5°C
369
488
732
976
1357
1595
1904
2832
3784
+10°C
0°C
-10°C
290
387
589
779
1083
1273
1523
2261
3023
+5°C
-5°C
-15°C
248
331
496
662
928
1089
1297
1964
2606
0°C
-10°C
217
288
433
577
815
958
1154
1761
2332
-5°C
-20°C
193
257
386
514
732
863
1035
1583
2106
-10°C
-15°C
177
236
353
471
672
791
958
1464
1940
-15°C
-20°C
-26°C
162
217
325
433
619
726
887
1345
1785
-20°C
-26°C
151
201
301
402
576
678
821
1250
1654
-26°C
140
187
281
375
538
631
762
1160
1547
PDP outlet
34
45
67
90
129
151
185
280
370
8 bar
Purge air in l/minute at 8 bar *
* the intrinsic permeability is approx. <5% relating to the purge air volume.