13. Remove the pilot valve seat with the core guide pipe
and the screws.
14. Replacement of the anchor system comprising magnetic
core guide pipe and core:
• Remove the core guide pipe and core with the retaining
plate.
• Pull the anchor system down and out of the retaining
plate.
15. Insert a new anchor system into the retaining plate from
below.
Set the core guide pipe onto the pilot valve seat.
16. Remove switch-over valve seat, rotate by 180° and place
in front of the control unit.
• Remove the piston with spring and seal from the switch-
over valve seat.