3.3 Function description
Illustration
Description / explanation
C
21
46
The condensate flows via the condensate inlet
[C]
into the
BEKOMAT
®
and collects in the housing
[21]
. The filling
level in the housing
[21]
is permanently monitored by a
capacitive sensor in the sensor tube
[46]
.
30
25
B
The control actuates the pilot valve with valve core
[30]
and the membrane
[25]
opens the condensate
discharge
[B]
to the condensate drain system.
Once the
BEKOMAT
®
has been emptied, the condensate
discharge
[B]
is closed tightly again before any loss of
compressed gas can occur.
BEKOMAT
®
16 CO
Original installation and operation manual
12 | 60