Wrong
Right
Description / explanation
Deflecting surface!
In the case of direct drainage from the compressed
gas line a deflection of the compressed gas flow is
necessary!
Continuous slope!
If a pressure hose is used for inflow, avoid the
formation of a water pocket!
Continuous slope!
When laying pipes for the feed line, avoid the
formation of a water pocket.
Continuous slope!
Lay the condensate inlet line with a continuous slope!
If the installation height is limited, mount the lower
inlet with a separate venting line.
Note the minimum height of installation!
The height of the condensate inlet must be located
lower than the lowest point of the collecting tank (e.g.
vessel).
BEKOMAT
®
16 CO
Original installation and operation manual
22 | 60