9.1 Operating states
Illustration
Description / explanation
Disconnected
•
All LEDs are off
Switch on / power-on self-test
• All LEDs light up for 1 second
n = 2
Positive power-on self-test (repeat 2x)
•
The red Alarm LED is off
• The green Valve LED lights up during the solenoid
valve cycles
• The green Power LED is on
• The solenoid valve cycles
0
goes into normal operation
n = 20
n = ∞
Negative power-on self-test (repeat 20x)
• The red Alarm LED is on
• The green Valve LED lights up during the solenoid
valve cycles
• The green Power LED is on
• The solenoid valve cycles
0
Goes to fail-safe operation (continuous loop)
• The solenoid valve cycles once per second
Ready for operation (normal operating mode)
•
The red Alarm LED is off
•
The green Valve LED is off
• The green Power LED is on
Discharge procedure
•
The red Alarm LED is off
• The green Valve LED lights up during the discharge
procedure
• The green Power LED is on
Pre-alarm (permanent loop)
•
The red Alarm LED flashes
• The green Valve LED is on
• The green Power LED is on
Alarm
• The red Alarm LED is on
•
The green Valve LED is off
• The green Power LED is on
For further information about fault indications during operation see
“15. Troubleshooting / FAQ” on Page 53.
Fail-Safe
BEKOMAT
®
16 CO
Original installation and operation manual
34 | 60
Summary of Contents for BEKOMAT 16 CO
Page 1: ...EN BEKOMAT 16 CO 01 3582 Original installation and operation manual BM16CO ...
Page 55: ...Original installation and operation manual BEKOMAT 16 CO 55 60 ...
Page 58: ...BEKOMAT 16 CO Original installation and operation manual 58 60 ...
Page 59: ...Original installation and operation manual BEKOMAT 16 CO 59 60 ...