Installation and Operation Manual
BEKOKAT
®
44 / 88
V01 /11-046
4.3
Bypass System
The bypass system should be equipped with an automatic bypass valve and installed as
follows:
1
BEKOKAT
®
2
CLEARPOINT
®
particle filter as afterfilter with
BEKOMAT
®
3
CLEARPOINT
®
ultra-fine filter as bypass filter with
BEKOKAT
®
4
CLEARPOINT
®
Activated-carbon adsorbers
5
CLEARPOINT
®
particle filter as afterfilter
6
Automatic BYPASS VALVE for
BEKOKAT
®
H1, H2
shut-off ball valve
H3, H4
shut-off ball valve, oil and grease-free model
R1, R2
Check valve, oil and grease-free version