Installation of compressed air connection
The compressed air connection of the
BEKOKAT
®
is located on the valves for inlet and
condensate drain (see illustration).
The connection is designed as a
cylindrical internal thread Rp 2 1/2 " in accordance to
DIN EN 10266-1
.
Proceed as follows to connect the BEKOKAT
®
to the compressed gas system:
1.
Connect
BEKOKAT
®
professionally to the compressed air line.
2.
Inspect compliance with the safety instructions relating to the
quality of the
compressed air.
Refer to the "Assembly” chapter.
3.
Inspect all bolt fittings for correct seating and tightness.
4.
Inspect the correct connection of the inlet and outlet pipes to the assembly unit.
5.
Subsequently initiate a leak tightness examination for the whole installation.