Installation and Operation Manual
BEKOKAT
®
V01 /11-046
17 / 88
1.5
Special safety instructions
DANGER
Compressed air parameters
Exceeding the maximum pressure can cause damage to the plant.
Observe the maximum permissible pressure specified on the rating
plate!
NOTE
Endangered functional safety
Faulty installation can endanger the functional safety and have a
negative effect on maintenance work.
The clear width of the pipe connection must be at least as large as
the connection dimension of the
BEKOKAT
®
.
It is strongly recommended that a shut-off valve be installed before
and after the
BEKOKAT
®
for maintenance work.
Furthermore, it is strongly recommended to provide the
BEKOKAT
®
with a lockable bypass line.
Overloading of the
BEKOKAT
®
can endanger functional safety!
Always observe the permissible temperature and pressure range!
Do not exceed the permissible volume flow rate and the permissible
operating pressure!
Do not undershoot the working pressure!
NOTE
Maintenance works
All maintenance work on the
BEKOKAT
®
may only be executed
when the catalytic converter is switched off, depressurised and
voltage-free.
The removal of seals and labels on safety equipment is prohibited.