18
Gateway 70 588
Chapter 3
| Configuration
The following feedback can occur:
Status messages (blue highlighted)
Contents
Explanation
Initializing
The gateway has recently been booted and is about to be ready.
The ZigBee network is being discovered via gateway, to
discover existing components and to integrate them into your
ZigBee system. This procedure may take a few minutes...
At initial operation the gateway will automatically scan your
ZigBee network to find installed components. Only after this
procedure you will be able to control these components via app.
ZigBee network discovery via gateway completed. No new
components were found.
No ZigBee components were found while scanning your ZigBee
network. In case, that installed components couldn’t be found
due to external interferences, you have the option to manually
start a network scan via app.
ZigBee network discovery via gateway completed. One (or
more) new component(s) were found.
The exact number of ZigBee components found during
the network scan will be displayed. In case, that installed
components couldn’t be found due to external interferences, you
have the option to manually start a network scan via app.
A new component (IEEE address: 00:1F:EE:00:00:00:00:01)
was found and integrated into your ZigBee network.
Every ZigBee component found can now be clearly identified by
its IEEE address (EUI-64).
New devices can now be connected with your ZigBee
network.
An access code for adding a new control device has been
enabled via the web interface. To activate a control device in your
ZigBee network, enter this code on the device to be added.
The device (iPhone John Doe) now has access to your ZigBee
network.
Access to your ZigBee network has been successfully granted to
the new control device.
The device (iPhone John Doe) has no access to your ZigBee
network.
Access to your ZigBee network from now on is denied the control
device. Reactivating access is only possible by a new access
code.
The update of the network component with the IEEE
address: 00:1F:EE:00:00:00:00:01 has been successfully
completed.
A new firmware for a ZigBee component has been downloaded
and will be installed afterwards. After successful installation, the
component restarts and will then be available again.
Warning messages (orange highlighted)
Contents
Explanation
A command directed to the component (network address
1234) failed (status code: NWK:ROUTE_ERROR).
This error may occur, if the component is temporarily not
available.
This is usually a temporary radio transmission interference in your
ZigBee network, wherein control commands cannot be sent to
the target device.
This kind of error is often caused by external parasitic induction
and will be automatically fixed by the intelligent radio standard
being used.
If this warning message is displayed repeatedly, check, if the
affected component is installed and properly connected to power.
Do the same for temporarily stored ZigBee routers.
A command directed to the group (group address 0001) failed
(status code: MAC:CHANNEL_ACCESS_FAILURE).
This error may occur, if the component is temporarily not
available.
This is usually a temporary interference or overload in the ZigBee
network, wherein control commands cannot be sent to a group of
controlling devices.
This kind of error is often caused by external parasitic induction
or massive radio traffic and will be automatically fixed by the
intelligent radio standard being used.