Display and operation - Graphical user interface
User Manual PoolManager
®
13
7.5.1
Calling up quick info
To call up quick info, the normal address for remote access (IP
address or URL) is attached along with the following suffix:
/cgi-bin/webgui.fcgi?infoframe=0
Thus, a complete URL would be, for example
http://myPoolManager.dtdns.net/cgi-bin/webgui.fcgi?infoframe=0
This URL is relatively complicated, but it can easily be stored in the
browser as a favourite.
TIP
Multiple devices at a glance
If you are a specialist handling multiple PoolManager
®
units, you can have the quick info of all relevant
devices displayed jointly on one webpage.
This means you'll have the most important information
from all devices in one place.
If, for example, there is a device showing an alarm (red
text), then you can directly access the device with one
click.
8
Display and operation - Graphical user
interface
Display and operation are realised on a large TFT colour display with
touchscreen. The function shown can be executed with the simple tap
of a finger on the corresponding area on the screen. Each tap on the
touchscreen is confirmed with a signal tone.
To the right of the display, there are 5 "hotkeys" for important standard
functions. The hotkey functions are also confirmed with a simple finger
tap and confirmed with a signal tone.
Menu (main menu)
Direct jump to main menu (icon menu)
Esc (escape)
Back to previous menu level
Home (home view)
Direct jump to home view
Help (help)
Display help text for the current menu
Mode (mode menu)
Direct jump into mode menu for turning on various functions
quickly and simply
8.1
Important menus
8.1.1
Home view
Home view is the standard view. It can usually be seen on the screen
and provides an overview of all important data and operating statuses.
Home view can called up at any time using the home hotkey.
1
Measured value shown with graphic measured value scale
2
Operating status and dosage status
3
Alarms
4
Supplemental functions
The areas 1, 2, and 3 mutually relate to a measurement or control
module, such as pH, redox, chlorine, or temperature.
1 Measured value shown with graphic measured value scale
Colour of measured value display:
green
Normal operation, everything OK
‘
yellow
Dosage blocked (missing flow
signal and/or start delay)
red
Alarm, dosage blocked!
1
Display for current measured value
2
Setpint (numeral value or mark)
3
Lower alarm threshold
4
Upper alarm threshold
2 Operating status and dosage status
1
Operating mode and/or operating status
2
LED indicates whether the dosage pump
is currently running
3
Dosage equipment
D- Decrease in measured value
D+ Increase in measured value
4
Current dosing output as %
Example: 10% means that the dosage
pump is turned on for 10% of the
available time. It will then run,
for example, for 6s
if the dosage cycle is set to 60s.
5
Fill level in the corresponding barrel:
Sufficient volume available
Limited residual volume available
The barrel is empty and has to be
replaced