25
Filter pump control
User Manual PoolManager
®
60
Configuration power output 0/4-20mA
Relay output 'Filter pump
on/off'
Relay switch output for turning on the filter pump
(for conventional filter pumps or as
superordinate on/off switch for variable filter
pumps).
Power output used
Power output for triggering the filter pump.
Power for pump off
Entry of currents in [mA], which the power
output used sets for the various operating
modes.
Power for reduced output
Power for normal
operation
Power for increased output
25.3.2.3
External switches
The filter pump control can be linked with up to three external switches
or push buttons that facilitate turning on/off manually or activating a
certain operating mode.
The following settings can be configured:
Sub-menus
External switches
External switch
1 / 2 / 3
Selection of an input to which the external switch is
connected
(IN 1 [6] / IN 2 [7] / IN 3 [8] / IN 4 [9] / none)
Type of ext. switch
On/off switch or pushbutton
For on/off switch only
External switch on
Defines the operating mode when external
switch is
turned on:
•
Filter pump off
•
Normal operation / reduced output /
increased output
•
Filter pump AUTO,
(Operating mode controlled by PoolManager
®
)
External switch off
Defines the operating mode when external
switch is
turned off:
•
Filter pump off
•
Normal operation / reduced output /
increased output
•
Filter pump AUTO,
(Operating mode controlled by PoolManager
®
)
For
devices
only
Function of external
device
Toggle
off / normal / off / ... or
toggle
off / low / normal / high / off / ...
25.3.2.4
Dosage blocking
Here, you can defined the operating modes in which dosing is blocked
for pH control and disinfection.
Sub-menu
Dosage blocking
Dosage blocked for
reduced output
Yes / no
Dosage blocked for
increased output
Yes / no
HAZARD!
Gaseous chlorine produced from dosing
with too little water circulation
When dosing in water with very little circulation,
poisonous gaseous chlorine can be produced when
ChloriLiquid and pH minus meet.
Potential consequence: Death or the gravest
degree of injury,
heavy material damage.
•
Only active dosing for reduced output if good
circulation and quick transportation of the dosed
maintenance produced are secured.
•
In cases of doubt, block dosage for reduced output.
INFO
Dosage for increased output
pH and redox measurement are generally barely
affected by flow. Therefore, it is not absolutely
necessary to block dosing for increased output.
For
maximum
safety,
however,
blocking
is
recommended.
25.3.3
Safety settings
HAZARD!
Hazard via remote access to
filter pump control
Turning on a filter pump in remote access can yield
hazards
for
swimming
guests
(e.g. due to current or suction effects).
Potential consequence: Death or the gravest
degree of injury, heavy material damage.
•
Remote access to filter pump control is expressly
PROHIBITED for all applications in which the
safety of persons, animals, and property is not
completely guaranteed at all times and under all
circumstances.
•
Safety is exclusively in the system operator's
sphere of responsibility.
•
The device manufacturer disclaims all liability.
The following security settings are available:
Sub-menu
Safety settings
Allow remote access
Potential settings:
•
Inactive
•
Local network
•
Local network & Web
Display in
Mode menu
Yes / no
25.4
Electrical connection
Requisite user qualification:
ELECTRICAL SPECIALIST
Electrical connection of filter pump control may only be
performed by an ELECTRICAL SPECIALIST as
defined in the chapter
User qualification.
IMPORTANT NOTICE!
Observe maximum flows
Observe the maximum permissible currents for each
individual relay switch output (max. 4A) and for the sum
of all relay switch outputs being used in 230V~ (in sum,
max. 4A)
Please also refer to the Chapter
230V~ Power supply.
The connection options already described for universal switch outputs
are possibilities for connecting a conventional filter pump; see
Universal switch outputs
connection options.
The connection of a variable filter pump is shown schematically in the
following figure.