Measured value graph
User Manual PoolManager
®
25
Measurement graph with mutual display of two measured
variables
(pH and mV (redox)):
1
Selection keys for showing one or two measured variables
Pressing a key activates or deactivates display of the
respective measured variable.
The measured variables currently displayed have a light
background.
A maximum of 2 measured variables can be activated (it
may be necessary to deactivate a measured variable first
before another can be activated)
2
Scale for the first measured variable shown (e.g. pH)
3
Scale for the second measured variable shown (e.g. mV)
4
Measured value curve for the first measured variable
(e.g. pH)
5
Measured value curve for the second measured variable
(e.g. mV)
6
Alarm status (flow only)
No alarm and/or flow alarm is indicated with a red bar
in the corresponding time frame.
Measurement graph with break
(PoolManager
®
was turned off):
1
Point in time turned off
2
Point in time turned on
The device was turned off between point in time 1 and point in time 2.
That is why there are no measured values shown for that range.
Measured value graph (BayroSoft):
1
During O2 (BayroSoft) dosing, the current dosage volume
is displayed in litres. The measured value curve climbs
from 0 to the total dosage volume. In this example, that
number is 2 litres.
2
The measured value curve shows 0 litres for times at
which no dosage is applied.
3
For better orientation, the programmed basic dosage
volume is shown.
9.2
Notes on Measurement graph:
The value range displayed (measured value scale) is set automatically
in order to ensure optimal display of the corresponding situation. The
value range can also be set manually as needed. However, we
recommend using automatic scaling.
•
The following alarm statuses are indicated in the measurement
graph.
Alarm
Designation
No flow and/or
flow alarm
Flow
Level alarm
Level
Dosing alarm
Dos.
•
Alarms are displayed for as long as they are active. It does not
matter whether they were acknowledged or not.
9.3
Configuration
The
configuration measurement graph
menu is called up from the
measurement graph using the menu button
.
The following table shows the menu's set-up:
Menu
configuration measurement graph
Configuration measurement
graph pH
Call-up configuration for the
pH measurement graph
Configuration measurement
graph mV
Call-up configuration for the
mV (redox) measurement graph
Configuration measurement
graph Cl
Call-up configuration for the
Chlorine (Cl) measurement graph
Configuration measurement
graph T
Call-up configuration for the
T (temperature) measurement graph
Configuration measurement
graph O2
Call-up configuration for the
O2 (BayroSoft) measurement graph
Export measurement graph
See section
measurement export