31
Universal switch inputs IN 1 ... IN 4
User Manual PoolManager
®
67
30.1.2
Basic configuration
The menu
Basic configuration
is used to configure the basic settings
for eco mode. This is generally done once at the start-up.
The following settings are available:
Sub-menu
Basic configuration
Relay output 'normal
mode'
Relay switch outputs used for both operating modes
Normal mode
and
Eco mode
(None / OUT 1 [26] / OUT 2 [27] / OUT 3 [30] /
OUT 4 [31] / pH+ [22] / pH- [21]).
In order to activate the Eco operation, it is sufficient
to allocate at least one of the two relay outputs.
Rely output
'Eco mode'
External switch or
push buttons
See
External switch or push button.
30.1.2.1
External switch or push buttons
The eco mode function can be linked with an external switch or device,
which facilitates turning the function on or off manually.
The following settings can be configured:
Sub-menu
External switch or push button
External switch
Selection of an input to which the external switch is
connected
(IN 1 [6] / IN 2 [7] / IN 3 [8] / IN 4 [9] / none)
Type of external
switch
On/off switch or device.
For on/off switch only
External switch on
Defines the operating mode when external
switch is
turned on:
•
Eco mode
•
Normal operation
•
AUTO,
(Operating mode controlled by PoolManager
®
)
External switch off
Defines the operating mode when external
switch is
turned off:
•
Eco mode
•
Normal operation
•
AUTO,
(Operating mode controlled by PoolManager
®
)
For
devices
only
Function of external
device
Toggle
eco mode / normal mode /
eco mode /
... (fixed setting)
30.1.3
Safety settings
HAZARD!
Hazard via remote access
Under certain circumstances, hazards can be yielded
from remote access to the eco mode function
depending on the concrete form of realisation.
Potential consequence: Injury,
material damage.
•
Release of remote access to the eco mode function
is expressly PROHIBITED for all applications in
which the safety of persons, animals, and property
is not completely guaranteed at all times and under
all circumstances; especially for remote access.
•
Safety is exclusively in the system operator's
sphere of responsibility.
•
The device manufacturer disclaims all liability.
The following security settings are available:
Sub-menu
Security settings
Allow remote access
Potential settings:
•
Inactive
•
Local network
•
Local network & Web
Display in
Mode menu
Yes / no
30.2
Electrical connection
Requisite user qualification:
ELECTRICAL SPECIALIST
The electrical connection for eco mode may only be
performed by an ELECTRICAL SPECIALIST as
defined in the chapter
User qualification.
IMPORTANT NOTICE!
Observe maximum flows
Observe the maximum permissible currents for each
individual relay switch output (max. 4A) and for the sum
of all relay switch outputs being used in 230V~ (in sum,
max. 4A)
Please also refer to the Chapter
230V~ Power supply.
Depending on how eco mode is realised, there are various options for
establishing the electrical connection (potential free, 230V~,...).
In general, the connection options already described for the universal
switch outputs are available, see
Universal switch output
connection options
.
31
Universal switch inputs IN 1 ... IN 4
PoolManager
®
provides four universal switch inputs that can be
connected to external potential free switches or switch contacts:
Universal switch
input
Description
IN 1 [6]
Switch input IN 1 [terminal block 6]
IN 2 [7]
Switch input IN 2 [terminal block 7]
IN 3 [8]
Switch input IN 3 [terminal block 8]
IN 4 [9]
Switch input IN 4 [terminal block 9]
Several of the potential applications are described in connection with
the various add-on functions, e.g. connection of an external switch of
push button.
IMPORTANT NOTICE!
potential free
The externally connected switch or switch contact
absolutely must be potential free (voltage free).
Otherwise, residual currents may arise, which can,
among other things, destroy electronic components.