Congratulations on your purchase of the Electronic Pooltester. 

The tester is a battery-operated measuring device which deter-

mines the specific dissolved matter together with the included 

reagent tablets. The tester and the tablets are only intended 

for the designations mentioned in the table in non-commercial 

applications and may not be used for other purposes. Please 

read through this manual and the special instructions carefully 

before using it for the first time.

Important notes

Tablet reagents are intended for chemical water testing and 

analysis only and may not be used for other purposes.

Caution

Potentially harmful if the tablet reagents are swallowed.

Do not swallow

Keep the tablet reagents out of the reach of 

children.

If swallowed, you can contact the Poison Center Berlin, 

Germany tel. no.: +49 30 30686 790 or find information 

in the safety data sheets with information on the risks 

and first aid measures at www.lovibond.com/support 

Download MSDS by entering the product name of the 

reagent tablets.

Before you start

Insertion and replacement of batteries: 

Battery type 2 x AAA, LR 03, 1.5 V.

Only perform when the device is dry: Open the battery 

compartment on the underside of the device. Pay attention to 

the correct polarity of the batteries. Make sure that the battery 

compartment cover is firmly seated when closed.

Attention: Do not use rechargeable batteries!

Replace the batteries if this symbol appears in the 

display.

Error messages

No.

Meaning and possible causes

01

Insufficient light at ZERO. Poss. cause: Sample 

chamber contaminated or light path blocked; sample 

strongly coloured?

03

Division by 0. Poss. cause: Sample chamber 

contaminated or light path blocked; sample strongly 

coloured?

20

Too much light at detector. Poss. cause: Cap not 

applied; measurement in bright sunlight

21

Too much light at detector. Poss. cause: Cap not 

applied; measurement in bright sunlight

22

LowBat occurred during measurement. Change 

battery, clean contacts

•  Maintenance

 

1.  Keep the instrument in a clean condition.  

 

2.  No solvent, abrasive materials or brushes  

 

should be used to clean the instrument. Clean  

 

the sample chamber using a soft tissue. 

 

3.  Dry the instrument when not in use, store under  

 

ambient environmental conditions. 

4.  Remove battery if instrument is being stored for 

 

an extended period.

•  Trouble shooting

1.  Use only blister tablets with black printing.

2.  Do not touch the tablets. This can cause  

 

 

contamination and give pour results.

3.   Close the blue lid on top of the sample chamber 

tightly before zeroing/reading.

4.  Always ensure that the sample chamber, the lid  

 

and the stirring rod are thoroughly rinsed when 

 

changing from one test to the other. 

Warranty

The waterproof Electronic Pooltester is warranted to be 

free from manufacturing defects for two years.

Ideal values

CyA

< 100 mg/l

ClF

between 0.5 and 2 mg/l

Cl

combined < 0.5 mg/l 

(Cl combined = ClT-ClF = (DPD1+DPD3)-DPD1 

Br

between 1 and 3 mg/l

TA

> 80 mg/l 

pH

between 7.0 and 7.4 (water treatment with chlorine 

or active oxygen) and between 7.0 and 7.6 (water 

treatment with bromine)

Summary of Contents for 287300

Page 1: ...so Manual de instrucciones Gebruiksaanwijzing Betjeningsvejledning Bruksanvisning Bruksanvisning K ytt ohje Free Chlorine Freies Chlor Total Chlorine Gesamtchlor pH Cyanuric Acid Alkalinity Alkalinit...

Page 2: ...Spegnimento automatico Automatisk sluk Automattinen sammutus 300 sec Ambient Conditions Umgebungsbedingungen Conditions ambiantes Conditioni ambientali Condiciones ambientales Omgevings condities omg...

Page 3: ...mbol appears in the display Error messages No Meaning and possible causes 01 Insufficient light at ZERO Poss cause Sample chamber contaminated or light path blocked sample strongly coloured 03 Divisio...

Page 4: ...ng range HIGH Measuring range exceeded RepeatTest Press the Zero Test key Change Method Take new sample Press the Mode key to scroll down Perform test New zero Option Press the Zero Test key for 2 sec...

Page 5: ...Batterien wenn im Display dieses Zeichen erscheint Fehlermeldungen Nr Bedeutung und m gliche Ursachen 01 Zuwenig Licht bei ZERO M gl Ursache Proben kammer verschmutzt oder Lichtweg blockiert Probe sta...

Page 6: ...scrollen Test durchf hren Neuer Nullabgleich Option Dr cken derTaste Zero Test f r 2 sec Wichtiger Entsorgungshinweis zu Batterien Akkus Jeder Verbraucher ist aufgrund der Batteriever ordnung Richtlin...

Page 7: ...liser de piles rechargeables Remplacez les piles lorsque le symbole illustr s affiche l cran Les messages d erreur No Signification et causes possibles 01 Troppeudelumi re Z RO Causepossible Puitssale...

Page 8: ...r au dessus de la plage de mesure R p ter le test Appuyer sur la touche Z ro Test Autre m thode Prenez nouvel chantillon Appuyer sur le touche Mode et faire d filer Effectuer un test Nouvelle compensa...

Page 9: ...tterie ricaricabili Sostituire le batterie quando nel display appare questo simbolo Messaggi di errore N Significato e possibili cause 01 Poca luce con ZERO Poss causa Pozzetto imbrattato o raggio blo...

Page 10: ...rato Ripetere il test Premere il tasto Zero Test Altro metodo Prendere nuovo campione Premere il tasto Mode e scorrere Eseguire il test Nuova taratura a zero opzione Tenere premuto il tasto Zero Test...

Page 11: ...utilice pilas recargables Si aparece este s mbolo en la pantalla debe sustituir las pilas Mensajes de error N Significado y posibles causas 01 Muy poca luz estando en CERO Posible causa Caja sucia o c...

Page 12: ...aprox 6 segundos En la pantalla aparecer el resultado mg l O LOW Rango de medici n demasiado bajo HIGH Rango de medici n sobrepasado Repetir la prueba Presione la tecla Zero Test Otro m todo Tome nue...

Page 13: ...atterijen Vervangt u de batterijen wanneer in het display dit symbool verschijnt Foutmeldingen Nr Betekenis en mogelijke oorzaken 01 Te weinig licht bij ZERO MO schacht vuil of lichttraject geblokkeer...

Page 14: ...t display verschijnt weer het resultaat mg l Of LOW meetbereik onderschreden HIGH meetbereik overschreden Test herhalen Knop Zero Test indrukken Andere methode Neem nieuwe sample De Mode knop indrukke...

Page 15: ...ift batterierne n r dette symbol vises p displayet Fejlmeddelelser Nr Betydning og mulige rsager 01 For lidt lys ved ZERO M Kammer tilsmudset eller lysvej blokeret er pr ven st rkt farvet 03 Division...

Page 16: ...nnem valgmulighederne Udf r test Ny nulkalibrering option Tryk p ZERO TEST tasten i 2 sekunder Vigtige informationer vedr bortskaffelse af batterier og akkumulatorer I henhold til batteridirektivet 20...

Page 17: ...mbol visas p displayen Felmeddelanden Nr Inneb rd och m jliga orsaker 01 F r lite ljus vid ZERO MO Schakt nedsmutsat eller ljusstr ckan blockerad Provet kraftigt f rgat 03 Division genom 0 MO Schakt n...

Page 18: ...dra metoder Ta nytt prov Tryck p knappen Mode och bl ddra Utf r testet Ny nollst llning Alternativ H ll knappen Zero Test intryckt under tv sekunder Viktig information om omh ndertagande av batterier...

Page 19: ...bruk oppladbare batterier Bytt batteriene n r dette symbolet vises i displayet Feilmeldinger Nr Betydning og mulige rsaker 01 For lite lys ved ZERO M Er sjakten tilsmus set lysveien blokkert eller pr...

Page 20: ...underskredet HIGH m leomr de overskredetn Gjenta testen Trykk Zero Test knappen Annen metode Ta ny pr ve Trykk Mode knappen og scroll Utf r test Ny nulljustering alternativ Trykk p Zero Test knappen...

Page 21: ...heilmoitukset Nro Merkitys ja mahdollinen syy 01 Liian v h n valoa ZERO ssa SYY Lokero likainen tai valonmatka estynyt n yte voimakkaasti v rj ytynyt 03 Jaetaan nollalla SYY Lokero likainen tai valonm...

Page 22: ...olella HIGH Mittausalue ylittynyt Toista testi Paina ZERO TEST painiketta Muut menetelm t Ottaa uusi n yte Paina Mode painiketta ja vierit Suorita testi Uusi nollaus vaihtoehto Paina ZERO TEST painike...

Page 23: ...oltester 49 30 30686 790 www lovibond com support 2 AAA LR 03 1 5 1 2 3 4 1 2 3 4 Electronic Pooltester 2 01 03 0 20 21 22 CyA CyA 100 ClF ClF 0 5 2 Cl 0 5 ClT ClF DPD1 DPD3 DPD1 Br Br 1 3 TA TA 80 pH...

Page 24: ...0 5 Cl pH TA CyA Br Cl 6 ClF ClF DPD No 1 ClT Clt DPD No 1 DPD No 3 pH pH PHENOL RED PHOTOMETER CyA Stabilizer CyA Test TA ALKA M PHOTOMETER Br DPD No 1 7 8 15 9 ClF pH CyA Br 15 ClT TA 2 10 6 mg l LO...

Page 25: ...tirring rod 1 Instruction Manual Reagents and Assessories Ref 287301 Combipack consisting of 20 DPD No 1 tablets and 10 tablets each DPD No 3 Phenol Red CyA Alka M BAYROL Deutschland GmbH Robert Koch...