BAYKAL
EDITION NO :
APH
SECTION :
DATE OF ISSUE :
July-2005
PAGE :
77
1.
2.
3.
!
Remove the oil tank cap (Filling up point in Figure 6.6.3.1).
Open the valve under the oil tank to drain out the old oil completely (Draining
off point in
Figure 6.6.3.1
).
Note:
Insert a
discharge
hose
to the valve cock to
drain out old oil from oil tank to any tank.
Using a pump or a proper equipment, fill in new oil from the filling up point seen
in
Figure 6.6.3.1.a
Oil level must be seen in the middle of the oil indicator. Observe the oil level
from this indicator. Always keep the oil in same level.
When changing oil, keep the oil thank clean.
6.6.4. Changing the filter:
a. Changing return filter
The return filter element must be changed after first 200 hours of use, and then
every 1000 working hours
(See Figure 6.6.4.1).
Return filter is placed at the top
of machine. In order to change return filter element;
a.
Remove the bolts
(See Figure 6.6.4.2)
Return filter
Figure 6.6.4.1
Figure 6.6.4.2
BOLTS
Summary of Contents for APH Series
Page 17: ...BAYKAL EDITION NO APH SECTION DATE OF ISSUE July 2005 PAGE 17 Figure 5 1...
Page 90: ...BAYKAL EDITION NO APH SECTION DATE OF ISSUE July 2005 PAGE 90 APPENDIX A SPARE PART LIST...
Page 91: ...BAYKAL EDITION NO APH SECTION DATE OF ISSUE July 2005 PAGE 91 B HYDRAULIC CIRCUIT DIAGRAM...
Page 92: ...BAYKAL EDITION NO APH SECTION DATE OF ISSUE July 2005 PAGE 92 C ELECTRIC CIRCUIT DIAGRAM...
Page 93: ...BAYKAL EDITION NO APH SECTION DATE OF ISSUE July 2005 PAGE 93 ADDITIONAL MANUALS...