Page 42
16.18 To remove the main burner injector.
(See figure 47).
1.
Remove the burner (See section 16.17).
2.
Remove the burner clamping screw (See figure 47).
3.
Unscrew the injector from the burner.
4.
Refit in the reverse order.
16.19 To remove the appliance from the fireplace.
1.
Remove the burner unit (See section 16.12).
2.
If the fire retention is as method 1 (See section 9.1 of
this guide), remove the screws.
If the fire retention is as method 2 (See section 9.2 of
this guide), slacken the hexagonal adjusters on the cable
retainers and unscrew the thumbscrews to release the cables.
3.
Refit as described in the relevant installation sections. Make sure gas soundness,
sealing, spillage test and performance are satisfactory.
©
Baxi Heating U.K. Limited 2010.
Figure 47. Main burner
injector removal
INSTALLER GUIDE