INSTALLER GUIDE
Page 27
10.3 Inlet pressure check.
The appliance is pre-set to give the correct heat
input at the inlet pressure shown in section 2 of
this manual. No adjustment is necessary.
1.
Ensure that the appliance is switched OFF, then
fit a pressure gauge at the test point (See figure
25).
2.
Check the pressure with the appliance alight
and set at maximum output.
3.
After checking, turn off the appliance. Remove
the pressure gauge and replace the test point
sealing screw.
4.
Test around the sealing screw for gas
soundness with a suitable leak detection
fluid.
5.
Fit the burner baffle to the front flanges
of the burner. To do this, locate the tags
on the baffle over the front flanges of the
burner and lower into position (See figure
26).
6.
It is advisable at this stage to remove
the battery to avoid accidental ignition
whilst fitting the ceramic fuel effect.
11. FITTING THE CERAMIC FUEL EFFECT
The installer and owner guide for the ceramic fuel effect is supplied with the ceramic
fuel effect. It is important that the fitting guide for the ceramic fuel effect be placed
inside or attached to this guide and handed to the customer following completion of
the ‘Final review’ section.
©
Baxi Heating U.K. Limited 2010.
Figure 26. Burner tray trim location
(Trim design may differ from that
shown)
Figure 25. Pressure test point