INSTALLER GUIDE
Page 12
3.9 Fireplace clearances.
3.9.1
The minimum height from the base of the fireplace opening to the underside of
any shelf made from wood or other combustible materials is detailed below.
•
For a shelf up to 150mm deep
: Minimum height = 700mm.
•
For a shelf deeper than 150mm
: 700mm + 12.5mm for every 25mm depth over
150mm (See figure 2).
3.9.2
The minimum allowable distance from the outside of the fascia to a corner wall
having combustible material or any other combustible surface which projects beyond
the front of the appliance is 100mm.
For access purposes a 10mm clearance to non-combustible surfaces is
recommended on the left side of the appliance, on the right side the recommended
clearance is 50mm for access to the slider control.
©
Baxi Heating U.K. Limited 2010.
Figure 2. Combustible shelf clearances