INSTALLER GUIDE
Page 22
9.
There is a length of self adhesive foam seal
supplied with the fire. This will need to be fitted to
the outer rear edges of the side and top flanges
of the convector box. Cut a 485mm length of
foam seal. Be careful not to stretch the seal
when measuring. Remove the protective backing
from the foam seal and fit this to the rear of the
top flange (See figure 16). Cut two 580mm
lengths. Fit these to the rear outer edges of the
side flanges. Ensure that there is no gap
between the foam seals where they meet at the
top flange (See figure 16).
9. CONVECTION BOX INSTALLATION
9.1 Method 1 - Front fixing to fireplace surround.
1.
Make sure that the fireplace front surround area is sound enough to take the fibre /
wooden plugs and woodscrews. If necessary, make
sound with suitable cement.
2.
Place the convection box centrally in the fireplace
in the position in which it is to be permanently
installed. If a concealed connection is being used,
insert the convection box into the fireplace feeding
the supply pipe through the pierced hole in the rear
grommet.
3.
Mark the fireplace front surround through the four
fixing holes in the side flanges of the convection box
(See figure 17).
4.
Remove the convection box. Drill four holes in the
fireplace front surround at the marked positions using
a suitably sized masonry drill for the fibre / wooden
©
Baxi Heating U.K. Limited 2010.
Figure 16. Fitting the foam seal
Figure 17. Front fixing